2.2.4 Coil Connector Test
Loop the coil cable and hold against side of the control box, approximately
250mm from the coil connector. Grasp the coil cable 75mm from the coil connector
and gently turn 30 degrees side to side, listening for a change of threshold. If there
is a noticeable threshold change (ie similar in volume to test piece threshold
change), the Coil should be replaced (Section 3.4) or the F1A4 should be sent to an
accredited F1A4 Level 2 maintenance workshop for repair.
2.2.5 Noise Cancel Test
Momentarily press the NOISE CANCEL button.
The F1A4 should immediately “beep”.
After 70 seconds the F1A4 should “beep” four times:
BEEP BEEP BEEP BEEP
If the correct tones are not heard the faulty Control Box should be replaced or
the F1A4 should be sent to an accredited F1A4 Level 2 maintenance workshop for
repair.
2.2.6 Audio Reset Test
Momentarily press the AUDIO RESET button.
The F1A4 should immediately BEEP.
After 3 seconds the F1A4 should give five “high / low” beeps:
BEEP
BEEP
BEEP
BEEP
BEEP
The threshold tone level should now be set at the correct operating level (ie
just audible). If the correct tones or threshold level are not heard the faulty Control
Box should be replaced or the F1A4 should be sent to an accredited F1A4 Level 2
maintenance workshop for repair.
2.2.7 Earset Test
1. Connect the Earset to the Control Box and ensure that the threshold tone is
audible at the earphone.
2. If a volume control is fitted, ensure that it operates correctly.
3. If the Earset does not operate correctly it should be replaced or the F1A4
should be sent to an accredited F1A4 Level 2 maintenance workshop for
repair.