8 F1A4 Operator Instructor Notes and Syllabus
Minelab Countermine Division Safety through Excellence
Nineteen
Disassembly.
Reverse the procedure to demonstrate disassembly. While disassembling place each
component back into the Compact Bag paying particular attention to the:
Correct location of each component as shown on the reverse side of the field
guide.
Yellow alignment line in the base of the Compact Bag to illustrate the correct
orientation of the handle.
Correct folding of the Upper and Lower Shaft to fit properly into the Compact Bag
(this may take several demonstrations) – Upper and Lower Shaft Camlocks are
to be locked but the Handle Camlock unlocked.
Need to remove the batteries from the Control Box.
Replacement of Dust Caps as required.
Test Piece being correctly stowed into the Control Box Bag.
Have the students take turns assembling and disassembling and watch for incorrect
procedures. Alternatively, select one student to assemble the detector with the rest of
the class reporting faults as they occur. The same method can be used for
disassembly.
Twenty
QUESTIONS
Students shall be able to correctly assemble and disassemble the detector with no
faults.
Faults to check for include:
Incorrect alignment of Shafts.
Failure to unlock a Camlock when trying to insert or remove the Shaft or
Armrest.
Incorrect positioning of Grommet.
Incorrect method of inserting batteries into the Battery Carrier.
Failure to turn the Handle Locking Pin to the locked position.
Failure to “click” Coil Connector into the locked position.
Incorrect folding of Shafts before placement inside the Compact Bag.
Failure to place the Test Piece back into the Control Box Bag.